PLANT DETECTIVE / ADVANCED AUTOCAD PLANT 3D MODEL ANALYSIS
Analyze connected systems.
Investigate the physical model.
Explore piping topology, cross-drawing relationships and equipment connectivity. Plant Detective adds structured model investigation and visualization alongside your Data Manager workflow.
01 / PROJECT-WIDE PIPING SYSTEMS
Read the connected structure across drawings.
Build project analysis data to inspect physically connected piping systems, grouped services and component membership with drawing references. Use Systems Overview for aggregate context and Piping Systems for the connected network behind a line or service.
Investigate where services extend, which components belong to a system, and which relationships deserve closer review. A line number is metadata; physical connectivity provides another way to understand the modeled structure.
Only available, successfully extracted drawing data contributes to project results. Review incomplete builds and rebuild after edits; refreshing a view reloads saved data rather than extracting the model again.
Build and review piping networks
02 / PIPING RELATIONSHIPS
Separate line identity from physical connectivity.
Inspect grouped findings for disconnected or split same-line-number groups and cross-line, cross-specification and cross-service bridges. Review inferred service or line assignments and missing or inconsistent information alongside connected-line results.
Expand a group and use available row actions to locate the underlying components. A repeated line number can describe separate physical groups; a bridge can be intentional. Judge findings against the source model and your project conventions rather than treating every category as an error.
Review piping relationships
03 / PIPING VISUALIZATION
Choose the condition. Investigate its objects.
Drawing review cards include Isolated Components, Disconnected Same Line #, Missing Line #, Missing Service, Equipment Boundaries, Open Ports, Cross-Line Bridges, Cross-Spec Bridges and Cross-Service Bridges. Review Services and Review Line Numbers help investigate inferred assignments; XREF Boundaries and Endtype Pairs provide additional review categories.
Apply an overlay and read its legend, then use available Select, Zoom or isolation actions. Project review includes project-system coloring and loaded-Xref tools. The project missing-service card is labelled Missing Services; the drawing card is Missing Service.
Highlighting does not repair connections or change metadata. Availability of drawing and Xref objects limits navigation. End Isolation restores visibility; Clear Highlights clears overlays.
Use piping visualization
04 / EQUIPMENT ANALYSIS & VISUALIZATION
Connect nozzle conditions to equipment relationships.
Use Overview and Nozzles & Lines to compare equipment tags, nozzle status, connected parts, services and line numbers. A connected nozzle with missing line information differs from an unconnected nozzle.
Equipment review cards cover unconnected nozzles, connected lines with no service or line number, cross-Xref connections, equipment-connected pipe networks, floating pipe networks, equipment with no reachable equipment, and all equipment connections. Drawing cards select available objects; project cards zoom to available targets, with separate highlight controls.
Connected Equipment shows reachable equipment and selected route components. Equipment Map uses project topology regardless of the workspace scope selector; its drawing filter narrows the display. Incomplete project caches can omit relationships.
Equipment analysis and visualization workflow
05 / CONNECTION RULES
Define the reference.
Review the connections.
Create Required, Allowed or Forbidden connection rules from a specification or connected drawing parts. Choose family matching for reusable definitions or size matching for exact component identities.
Review modeled connections against saved definitions. Filter status results, investigate Undefined pairs and highlight relevant components. Undefined means an unclassified pair, not necessarily a model defect. A Required status alone does not prove that every intended connection exists.
Connection Rules workflow
06 / ROUTE FINDING
Trace a path.
Keep the context.
Choose two components to calculate a shortest connected route in the loaded drawing or project topology. Inspect the ordered components, drawings and cumulative modeled distance.
Save a route for later review. Investigate connected branches and navigate to available components. Route finding analyzes connectivity; it does not perform flow or hydraulic analysis.
Route finding and saved routes
06 / ELEVATION PROFILES
Review how the route
rises and falls.
Inspect start and end elevation, extrema, net change, reversals and feature points. Connect profile points to the component rows and model navigation actions behind them.
Horizontal station and cumulative modeled distance are different measures. Missing elevation is incomplete information, not zero. Review the available geometry before interpreting grade or extrema.
Elevation profile workflow
06 / ROUTE VISUALIZATION
Compare routes
in model context.
Highlight the active route or selection, inspect its branches and color by line number, service, drawing or component grouping.
Overlay selected saved routes and selection sets to inspect shared physical components. Highlighting, selection and isolation are separate actions; restore visibility and clear overlays when finished.
Route visualization workflow
07 / ASSEMBLIES
Turn a connected arrangement
into a reusable definition.
Select connected parts to create a family-level or size-specific assembly definition. Review the saved members, schematic and snapshot where available.
Build drawing or project assembly data, inspect detected matches and missing or unmatched patterns, and use highlighting for visual review. Results are capped at 25 matches per definition; confidence is a review score, not a calibrated probability or an exhaustive count.
Assembly creation and detection
08 / DRAWING & PROJECT SCOPE
Know what your analysis includes.
Build Drawing Cache for an individual drawing or Project Cache for aggregate investigation. Systems Overview summarizes systems, services, components and equipment for the selected scope.
Project results depend on accessible drawings and successful extraction. Check build diagnostics before interpreting absent equipment or connections. Refresh reloads saved results; rebuild relevant data after changes.
Analysis scope and cache workflow
10 / DATA STORAGE
A rule store that fits your setup.
SQLite
Use a local rule store and configure writable application data locations for your workstation.
SQL Server
Not needed, but possible to use a shared application database for teams if desired. Configure and test the connection, then save the settings.
Drawing and project analysis caches remain separate SQLite files. Switching providers does not automatically move existing data; follow the documented copy and backup workflow.
SYSTEM REQUIREMENTS
Confirm your host before purchasing.
- Host: AutoCAD Plant 3D on Windows. Confirm the tested version and matching plugin build with CADPEAK before purchase.
- Runtime: The current plugin is available for Plant 3D 2025, 2026 and 2027.
- Licensing: A valid license is required. Online activation and license refresh require internet access; cached entitlement behavior depends on license state.
PLAN YOUR REVIEW
Practical tools. Engineering judgement.
Plant Detective supports investigation using available geometry, metadata and saved analysis. It does not guarantee compliance, completeness or engineering acceptance. Inspect relevant findings in the source model.
Plant Detective is independently developed by CADPEAK. CADPEAK is not affiliated with, endorsed by, or sponsored by Autodesk. AutoCAD and AutoCAD Plant 3D are trademarks of Autodesk, Inc.
PLANT DETECTIVE BY CADPEAK
Bring your model into focus.
Explore the software, review licensing or discuss your Plant 3D workflow.
