Tutorial
On this page

Configuring Settings and Licensing

Purpose

Set up the data locations and rule provider used by the team, and manage the license assigned to this computer.

Example

An administrator moves a design team from local SQLite rules to SQL Server, preserves the separate SQLite model caches, and prepares another workstation for license activation.

Prerequisites

Have writable storage locations, access to the intended SQL Server if used, and administrator-provided server/database/authentication details. Creating a database requires sufficient server permissions. Activation and self-service deactivation require licensing-service access. Back up the data involved before copying or changing locations.

Open Settings. Its pages are Database Provider, Data Storage, General, and License.

1. Choose the rule provider

  1. Open Database Provider.
  2. Choose SQLite for a local rule store, or SQL Server for the shared provider.
  3. Read Confirm Database Provider Switch.
  4. Choose Yes to change where rules are read/saved, or No to retain the existing provider.
  5. Read the result message.
  6. Restart AutoCAD if rule views/repositories were already open so all loaded views use the selected provider consistently.

Expected result: Provider selection is saved immediately after confirmation. Existing data is not moved automatically. Drawing/project caches remain SQLite files separate from the SQL Server persistent application database.

2. Configure and test SQL Server

  1. Select SQL Server so the SQL controls are enabled.
  2. Enter Server name: using the administrator's instance name.
  3. Choose Windows Authentication or SQL Server Authentication in Authentication:.
  4. For SQL Server Authentication, enter User name: and Password:. These fields are disabled for Windows Authentication.
  5. Enter the intended Database: name. Keep an existing team's database name unchanged unless deliberately connecting to a different store.
  6. Set Trust Server Certificate according to the server setup supplied by the administrator.
  7. Click Test SQL Setup and read the success/failure message.
  8. If the intended database must be created, click Create Database with an account permitted to do so.
  9. Click Save SQL Settings to persist the entered connection settings.
  10. Restart AutoCAD where already-open views need to adopt the new provider/settings.

Testing uses the values currently entered. A successful test is not a Save action. Creating the database is also a separate action. If SQL credentials cannot be read on this computer, re-enter them and save; do not assume a blank field represents the previously saved password.

Expected result: The connection can be tested independently, and saved settings persist for later sessions.

3. Copy SQLite data to SQL Server

The destination database must already exist; use Create Database separately if missing. Copy SQLite Data to SQL Server automatically initializes required destination schemas before the row-copy transaction. The SQL account needs schema-creation and row-write permissions. A successful Test SQL Setup establishes connectivity, not those permissions.

Equivalent records are skipped. Conflicts can roll back newly inserted rows in the row-copy transaction; schema initialization occurs beforehand and is not necessarily rolled back with the rows. Retain the report and seek administrator/CADPEAK help rather than deleting conflicting destination records.

  1. Select SQL Server and enter the intended target connection values.
  2. Test connectivity and confirm the target database is the intended one.
  3. Click Copy SQLite Data to SQL Server.
  4. Read the confirmation carefully. It uses the SQL settings currently entered; the copy action does not save those settings.
  5. Confirm Yes to copy, or No to cancel.
  6. Read the final result. The operation copies application data, skips equivalent records, and does not overwrite existing SQL Server records. Conflicts roll back new inserts.
  7. If you intend to keep this target, use Save SQL Settings separately.
  8. Restart if needed and verify the copied rule/definition data in its workspaces.

Expected result: Application data can be copied to the shared store. Drawing/project caches remain separate SQLite files. A conflict result is not evidence that all records were copied.

4. Configure Data Storage

Local application data

  1. Open Data Storage.
  2. Click Browse Data Folder.
  3. Choose a writable folder and accept the folder dialog.
  4. Read the updated displayed path. The choice is applied immediately; this page has no separate Save button.
  5. Use Open Data Folder to inspect the resolved location.
  6. Use Reset Data Folder to restore the default, and read/confirm its warning.

Changing/resetting a data path does not automatically move existing database files. An empty store at a new location does not mean the old data was deleted.

Drawing caches

  1. Choose Local app data folder or Plant 3D project folder.
  2. Read the change confirmation and accept only the intended location. The project-folder choice requires an appropriate active project.
  3. For a custom location, click Browse Cache Folder, confirm the change, then choose the folder.
  4. Read the resolved cache path.
  5. Use Open Cache Folder to inspect it.
  6. Use Reset Cache Folder to restore the local default after reading the warning.
  7. Rebuild the appropriate cache when data is absent at the newly chosen location.

Expected result: Future reads/builds use the configured locations. Existing cache files are not moved automatically.

5. Configure General storage

  1. Open General.
  2. Under Assembly Images, use Browse to choose the image folder, or type a path and click Save.
  3. Use Reset to restore the default.
  4. Read the result. Changing this location affects new assembly snapshots; existing records retain their stored image path.
  5. Under Saved Routes, use Browse, or enter the base folder and click Save.
  6. Read Current project: and the resolved project-library location.
  7. Click Open to open the active project's route-library folder.
  8. Use Reset to restore the default base location.

Browse and Reset apply their choices in these sections. Typing a path requires Save. Each Plant 3D project gets its own library beneath the base folder; changing the base does not move existing route files.

6. Activate and inspect a license

  1. When the activation screen appears, enter the organization's license key.
  2. Click Activate License and wait for the response.
  3. Read the activation status. A failure message must be resolved before assuming activation succeeded.
  4. Open Settings → License.
  5. Read Status, Licensed to, Subscription valid until, License changes remaining, Transfer status, and Subscription.
  6. Read expiry warnings before planning a workstation transfer or continued use.

The license page loads local status and checks transfer eligibility with the licensing service automatically. It does not expose a separate Refresh License button.

Renew and refresh entitlement

  1. Open Settings → License and read Subscription and Subscription valid until.
  2. Use Extend or renew license, or Extend license now when shown, to open the renewal page in your browser. If it cannot open or does not identify the expected product/account, contact CADPEAK Support.
  3. Reconnect this licensed computer to the internet and reopen Plant Detective. Normal license validation automatically attempts online refresh when the cached entitlement is nearing expiry or has expired; there is no separate Refresh License button.
  4. If the offline entitlement has expired, a successful online refresh is required before continued use, even when the subscription remains active.
  5. If refresh still fails, check the reported network/storage error and contact CADPEAK with the message and subscription details. Do not send the key/token or repeatedly deactivate the computer.

Subscription valid until is the license/subscription expiration date. Cached entitlement has a separate offline-validity limit, not displayed as that subscription date. A still-valid offline entitlement can remain usable if refresh fails; an expired one cannot. No fixed offline duration or payment-to-entitlement processing time is promised.

7. Set license storage

  1. Under License Storage, click Browse and choose a writable folder.
  2. Click Save to apply the displayed choice and move the computer's encrypted license storage.
  3. Read the result message.
  4. Use Open for the displayed folder.
  5. Use Reset to restore default local license storage.

Unlike the General/Data Storage folder selectors, License Browse only fills the path field; Save performs the change.

Plant Detective: Settings → License: License Storage
Settings → License: License Storage

8. Deactivate this computer for transfer

  1. Read License changes remaining and Transfer status.
  2. Check I understand the license transfer limit and want to proceed.
  3. Click Deactivate This Computer when enabled.
  4. Read the confirmation, including the remaining-change allowance. The final self-service deactivation has a specific permanent-binding warning on later reactivation.
  5. Choose Yes to proceed, or No to keep the current activation.
  6. Wait for a success result before treating the seat as released.
  7. Activate the license on the intended destination computer. This computer requires the key again if it is reactivated.

The action is disabled when eligibility cannot be verified, the computer is not active, or no self-service changes remain. Follow the displayed status/support guidance rather than repeatedly trying the action. Deactivation releases the seat and consumes the stated allowance.

Plant Detective: Settings → License: deactivation confirmations
Settings → License: deactivation confirmations

Important limitations

Copying excludes routes, images and separate SQLite model caches. Preserve repeat-copy conflict reports; do not remove destination records to force copying. Offline licensing is limited by valid cached entitlement. Deactivation is not subscription cancellation.

Next steps

Confirm the intended rule store by opening Rules → 2. Your Rules, then build caches and verify one normal workflow. Confirm saved route/image locations with a sample item rather than assuming old files migrated.

Search Plant Detective help

Type to search all 45 help pages.