Tutorial
On this page

Reviewing Equipment and Connected Equipment

Purpose

Find incomplete nozzle connections and trace the piping relationships between equipment.

Example

Review pump P-101: confirm its nozzles have connected lines, trace the connected vessel, and capture an equipment relationship map for the review meeting.

Prerequisites

Open the intended project/drawing and build Drawing Cache or Project Cache for Overview/Nozzles/Visualize. Equipment Map requires complete Project Cache topology regardless of the workspace scope selector. Equipment, tags, and nozzle information must exist in the model to be reported. Loaded Xrefs are needed for supported cross-drawing visual navigation. See cache and result controls.

1. Review Overview

  1. Open Equipment → Overview.
  2. Choose Current Drawing or Project using the equipment scope selector.
  3. Use the refresh control after cache completion if required.
  4. Search for the equipment tag.
  5. Read Equipment Tag, Equipment Type, Status, Nozzles, Connected Nozzles, and Unconnected Nozzles.
  6. Compare Connected With Line Number, Unknown Lines, and Line Numbers to distinguish connection from useful line identification.
  7. Read Xrefs, Drawing, and Summary for context.
  8. Use a row's zoom action or double-click to navigate to its available model target.
  9. Use the shared grid Filter, Data, and drawing actions where offered.

Expected result: You can distinguish an unconnected nozzle from a connected nozzle whose line information is missing. Counts describe the cached model, not unsaved/newly rebuilt information.

In project scope, extra actions include Select Displayed Equipment in Active Drawing and Isolate Displayed Equipment in Active Drawing. Their label deliberately limits the target to the active drawing.

2. Review Nozzles & Lines

  1. Open Nozzles & Lines, retaining the intended scope.
  2. Search for the equipment tag or desired line.
  3. Expand the nozzle tree and click a group/equipment/nozzle to restrict rows.
  4. Compare Tag, Type, Nozzle, Nozzle Size, Status, and Kind.
  5. Read Line Number, Service, Missing Info, Connected Part, and Drawing to explain the condition.
  6. Double-click a relevant row or use its zoom action.
  7. Use Filter → Include … on a status/line value to make a review set.
  8. Use the extra Select Displayed Connected Parts in Drawing or Isolate Displayed Connected Parts in Drawing action for the filtered connected parts.
  9. In Project, the corresponding actions say … in Active Drawing.
  10. Use End Isolation when finished and export displayed nozzle rows through Data if needed.

Expected result: The grid identifies individual nozzle connection conditions. A row without a connected-part target cannot be treated as a selectable connected pipe. Inspect the equipment/nozzle itself in the model when needed.

3. Trace Connected Equipment

  1. Open Connected Equipment.
  2. Choose Current Drawing or Project in Scope.
  3. Use Drawing to narrow available equipment where appropriate.
  4. Choose the source in Equipment, or click Pick and select it in the model.
  5. Wait for results. Changing the equipment automatically runs the connected-equipment search; there is no need to find a separate Find button.
  6. Use Search to narrow equipment, drawing, line, service, or distance information.
  7. Compare Connected Equipment, Type, Drawing, Modeled Distance, Direct Distance, Components, Line Numbers, Services, and Drawings Crossed.
  8. Select a connected-equipment row to load Selected equipment route.
  9. Read its ordered #, Drawing, Type, Family, Line, Service, Length, and Cumulative rows.
  10. Click Highlight Route to visualize that route or Select Route to select available route objects.
  11. Use the row zoom controls for the destination or individual route component.
  12. Click Clear Highlights when finished.

Modeled Distance follows the modeled route; Direct Distance is the direct separation. Compare them rather than assuming they measure the same thing.

4. Use Equipment Map

  1. Open Equipment Map after current project topology is available.
  2. Set Drawing and use Search for a tag/type/family. Ctrl+F focuses search.
  3. Toggle Labels for service/line/size/distance annotations and Legend for service colors.
  4. Choose ordered equipment/tee stops or toggle connection segments as described below.
  5. Click Highlight Route to reapply the selected route highlight.
  6. Use Clear Route to clear the map's route selection and Clear Highlights to remove model overlays.
  7. Use − and + to zoom the map. Drag its background, use middle-button drag, or hold Space while dragging to pan.
  8. Turn Lock off before dragging equipment/tee nodes to rearrange the map; turn it on to prevent further movement.
  9. Click Save or press Ctrl+S to preserve node positions.
  10. Use Reset to delete the saved layout and rebuild the automatic arrangement.
  11. Click Export to save the current map as a PNG image.

Expected result: A readable diagram illustrates equipment relationships. Layout changes affect the diagram, not model geometry. Saved layouts depend on the project and drawing-filter context.

Equipment Map always uses project topology. Its Drawing filter narrows displayed project information; it does not switch the underlying analysis to Current Drawing. Build current, complete Project Cache data for relevant project drawings before reviewing cross-drawing paths. Missing/partial project caches can leave equipment and connections absent; check build diagnostics, rebuild project data, then reopen or refresh the map.

Choose stops or connection segments

  • Click an equipment or tee node to append the next ordered stop. The map calculates through stops in click order.
  • Click the last stop again to remove it. Click an earlier stop to keep it and trim all later stops.
  • Click a connection line or label to toggle its segment. Adding adds endpoint nodes; removing removes endpoints no longer used by selected connections.
  • Clicking a node clears selected connection segments and returns to stop-based calculation. Segment selection composes selected connections rather than simply appending a stop. Read selection/status text: disconnected segments need not form one valid route.
  • Use Clear Route to reset the route and Clear Highlights to clear model overlays separately.

5. Visualize equipment conditions

  1. Open Visualize and choose Current Drawing.
  2. Read Equipment Review Cards.
  3. Click a review card to select its objects.
  4. Use Highlight for a visual review.
  5. Use Isolate Selected to reduce clutter and End Isolation to restore visibility.
  6. Use Clear Highlights to finish.

In Project, use review cards, legend Toggle Highlight and Zoom, and the provided loaded-Xref color/visibility/opening actions. Read status messages when components cannot be resolved in the current model context.

Interpret equipment review categories

Category Meaning in cached topology
Equipment with unconnected nozzles Nozzle/interface nodes have no connected topology edge.
Equipment connected to lines with no service Connection exists but connected service is blank, unknown or missing.
Equipment connected to lines with no line number Connection exists but connected line number cannot be resolved.
Equipment connected across xrefs Interfaces connect through an Xref/project boundary; current project topology is needed to detect these.
Equipment-connected pipe networks Service-based systems reach at least one equipment interface; service changes split systems, line-number changes do not.
Floating pipe networks Service-based piping systems have no equipment interface; review possible orphaned/incomplete fragments.
Equipment with no reachable equipment Equipment reaches piping but no other tagged equipment through topology; differs from an unconnected nozzle or floating network.
All equipment connections Connected interfaces, including direct and Xref connections.

In Current Drawing, clicking a card selects available objects. In Project, clicking a card zooms to available targets. Zoom changes framing, Select selects objects, and Highlight/Toggle Highlight adds or toggles overlays. These actions do not repair connections or fill metadata. Unavailable drawing/Xref targets can limit visual results; read status messages.

Plant Detective: Equipment → Visualize
Equipment → Visualize

Important limitations

Verify source drawings where filenames repeat. Analytical equipment-interface links do not establish internal process continuity or flow direction. Check distances and units against known dimensions.

Next steps

Correct missing nozzle/line information or unwanted connections, rebuild the relevant cache, and compare the counts. Continue to Routes to save a particular equipment-to-equipment path and review its elevation.

Search Plant Detective help

Type to search all 45 help pages.