Reviewing Piping Networks
Purpose
Understand connected piping systems and review line, service, specification, and port conditions.
Example
A cooling-water line appears in disconnected areas of the model. You need to distinguish legitimate branches from disconnected islands, find open ports, and locate cross-spec connections.
Prerequisites
Open the intended project and drawing. Build Drawing Cache, or Project Cache for a cross-drawing review, and wait for completion. See the shared cache workflow. These views read saved topology; refresh alone does not collect newly edited geometry.
1. Review Systems Overview
- Click Piping → Systems Overview.
- Choose Current Drawing or Project in Scope.
- Use the refresh icon (Refresh) after a completed build if results have not updated.
- Use Search for a service, system, or line identifier.
- Compare Service, System, Drawings, Lines, Components, and Equipment to understand each group.
- Read Pipe Length, Modeled Path, and Weight separately. They are distinct measures, not interchangeable totals.
- Read Low, High, and Elevation Span to identify systems with large vertical changes.
- Use the row's Zoom action to frame the system and select selectable components.
- Use Low Point or High Point to navigate to those extremes.
- Use Longest Path to review the connected path. In Current Drawing this zooms to the path; in Project it highlights the path across the active drawing and loaded Xrefs.
Expected result: One row describes a connected system with useful scale and extent information. In project scope, model selection still applies to selectable active-drawing components even when the view can frame Xref components.
2. Examine Piping Systems
- Open Piping Systems.
- Choose the intended scope and refresh if needed.
- Expand the service/system/line tree to the desired group.
- Click a tree label to narrow the grid; use search to narrow further.
- Read Service, System, Line, Role, Equipment Tag, Equipment Port, and Interface.
- Compare Type, Family, Size, and Spec for individual components.
- In Project, also read Drawing before navigating.
- Select a small group of rows and use the available Navigate, Highlight, Select in Drawing, or Isolate in Drawing actions.
- Clear grid filters, search, and tree restrictions independently when returning to the full system.
Expected result: You can distinguish the components assigned to a connected system from its equipment boundary information. Tree groups and grid rows organize the cached network; they do not modify line assignments.
3. Review Piping Relationships
- Open Piping Relationships and choose scope.
- Use Refresh if the view has not loaded the latest saved topology.
- Expand a finding group in the tree and click it.
- Compare Finding and Severity to prioritize review.
- Read Line A, Line B, Direct Line, and Review Line to understand which line assignments are being compared.
- Compare Current Service with Review Service, and Current Spec with Review Spec.
- Read Bridge / Component, Connected Lines, Equipment Tag, Equipment Port, Interface, and Note for the context of the finding.
- Right-click a finding or severity cell and use Filter → Include … for one review category.
- Select the relevant rows, zoom/highlight the available targets, and export the displayed review set through Data → Export Displayed Rows to CSV.
Treat findings as items to assess against design intent. A service or line suggestion is not an automatic model correction.
4. Check Open Ports
- Open Open Ports.
- Choose Current Drawing or Project and refresh.
- Expand the unconnected-port tree and click a group.
- Compare Spec, Type, Size, Port, End Condition, Diameter, and Unit. Current drawing also shows Display Size.
- In Project, check Drawing before selecting a result.
- Right-click a tree group and use Select Matching Parts or Isolate Matching Parts where offered.
- Use grid filters to isolate a particular port/end-condition value, then zoom to selected rows.
- Use End Isolation when finished.
Expected result: Rows describe unconnected ports. Several ports can belong to one component; do not read the row count as a unique-component count. A modeled open end can be intentional, so review it in context.
5. Compare Endtype Pairs
- Open Endtype Pairs and choose scope.
- Expand the pair tree and click a pair group.
- Read Pair, End A, Port A, Spec A, and Size A alongside the corresponding B-side fields.
- Compare diameter and unit fields when sizes appear inconsistent.
- Use Filter → Include … on the relevant endtype or spec cell.
- Use Select Matching Parts or Isolate Matching Parts from the tree where available, or the shared grid actions.
- Export displayed pairs to CSV for a connection-pattern review.
Endtype pairs describe connection patterns in the data. They are separate from the Required/Allowed/Forbidden policies in Connection Rules.
6. Visualize topology
- Open Visualize and choose Current Drawing.
- Click Color Systems to color connected systems.
- Choose a review card according to the problem:
- Review Services or Review Line Numbers for inferred/review assignments.
- Isolated Components or Disconnected Same Line # for connectivity grouping.
- Missing Line # or Missing Service for incomplete assignments.
- Equipment Boundaries or Open Ports for interfaces/open ends.
- Cross-Line Bridges, Cross-Spec Bridges, or Cross-Service Bridges for boundary connections.
- XREF Boundaries or Endtype Pairs for those patterns.
- Read Active Overlay and Current Color Legend to understand the displayed groups.
- Use a legend group's Select or Zoom action to focus on it.
- Use Select Overlay for the active overlay groups, or Isolate Overlay to isolate them.
- Use Additive Select: Off to toggle additive selection when combining selections. Recheck its current state before selecting another group.
- Use Isolate Selected for an existing model selection.
- Use End Isolation to restore visibility and Clear Highlights to clear overlays.
For Project, use Color Project Systems and the project review cards. Zoom Overlay frames available overlay targets; Show Only Highlight provides a focused visibility review. Loaded-Xref controls include Toggle Loaded Xref Colors, Clear Xref Colors, Hide Xrefs, Show All, Isolate Xrefs, Open Xref Component, and Open Component Read Only. These require appropriate loaded/available targets.
Next steps
Assess each finding against design intent, correct the model where needed, rebuild, and repeat the same filters. Export remaining findings for design review, or continue with Equipment and Routes to trace a particular connection.